Trunnions with Micarta ® G-10 Designed for a Cryogenic Pipeline

April 25, 2018

Trunnions Designed for a Cryogenic Pipeline at an LNG Facility

Type: Trunnions for Cryogenic Temperatures
Size: 8″-24″ Dia. | 12″-18″ L | 6″-15″ W | 6″-40″ H
Material: Micarta® G-10 Insulation | CS | SS
Design: Cryogenic Temperatures of -320°F
Testing: MTR’s | Non Destriuctive (PMI) | Q.C.

PT&P custom designed trunnions for a cryogenic pipeline at an LNG facility in Australia. The insulated supports were fabricated with carbon steel base plates, 304L stainless steel plates and fasteners. To prevent cryogenic temperatures of -320°F from transferring to the base of the trunnion support, Micarta® G-10 was used as insulator. The trunnions were designed to support pipe sizes from 8”-24” with dimensions ranging from 12”-18” in length, 6”-15” in width and 6”-40” in height. MTR’s were provided, and non-destructive testing (PMI) was preformed, along with standard Q.C. inspection prior to shipment.

This type of support is available in pipe sizes between 1/2″ to 42″ NPS; however, PT&P can customize any size needed. The standard material for these supports are galvanized or hot-dipped galvanized carbon steel. These supports were customized with Micarta® instead of the standard high density polyurethane with vapor barrier. When ordering, specify pipe size, insulation thickness and length. See more on Figure CS-6030 from our cryogenic pipe supports section.

Piping Technology & Products and Pipe Shields have been a major international supplier of pipe shoes and pre-insulated supports for more than 10 years. Our cryogenic pipe supports comply with the following standards ANSI / ASME B31.1 & B31.3 and The Manufacturers Standardization Society SP-58, 69, & 89.

Read More

Cryogenic Pipe Supports with Micarta® G-10 for an LNG Facility in Australia

April 16, 2018

Cryogenic Pipe Supports with Micarta® G-10 for an LNG Facility in Australia

Type: Cryogenic Pipe Supports
Size: Pipe Size of 1” to 36”
Material: LTCS Material Tops, Stainless Steel, & Micarta® G-10 Insulation
Design: -50°F
Testing: PMI

Piping Technology and Products supplied cryogenic pipe supports with axial stops for an LNG facility in Australia. The cold shoes were fabricated utilizing low temperature carbon steel, stainless steel and Micarta® G-10 insulation blocks. We supplied a wide range of lengths and pipe sizes from 1” to 36”. The cryogenic temperatures are low as -50°F. A special paint system was used for the low temperature carbon steel components to resist rust. PMI testing was performed on the stainless parts. Delivery was within 4-6 weeks.

Read More

High Temperature Pre-Insulated Pipe Supports with Slide Plates for an Ethylene Production Plant in Texas

March 27, 2018

High Temperature Pre-Insulated Pipe Supports for an Ethylene Production Plant in Texas

Type: High Temperature Pre-Insulated Pipe Supports with Slide Plates
Size: 15″ Long | 23″ Wide | 4.5″ Insulation
Material: Calcium Silicate, Firetemp®, Carbon Steel with HDG, UHMW Polyethylene
Design: 750°F, 1,325 lb Operating Load, & 12″ Pipe Size
Testing: Standard Quality Control

PT&P custom designed these pre-insulated pipe supports for high temperatures at an ethylene production facility in Texas. The hot shoes are 15″ long and 23″ wide with 4.5″ thick insulation. The insulation is comprised of calcium silicate and Firetemp®. The hot shoes were fabricated from carbon steel with a hot-dipped galvanized finish and the slide plates from UHMW Polyethylene. They are designed as a 2-way guide than can support loads in two directions. They are designed for a pipe size of 12″ in diameter with an operating temperature above 750°F and on operating load of 1,325 lb. Standard quality control tests were performed with a 4-week turn-around time.

Read More

Pre-Insulated Cryogenic Supports for Propylene Dehydrogenation

February 12, 2018

Pre-Insulated Cryogenic Supports for a Propylene Dehydrogenation Application at a Petrochemical Plant in Texas

Type: Pre-Insulated Cryogenic Supports
Size: 12” Long Base | 32” Wide Base | 62″ Overall Height | 18” Long Insulation
Material: Polyurethane | Carbon Steel w/ HDG Finish
Design: Operating Temperature -360°F & 42″ NPS
Testing: Standard Quality Control

Piping Technology and Products, Inc. and custom designed two pre-insulated cryogenic supports for a propylene dehydrogenation application at a petrochemical plant in Texas. The insulation is made from a high density polyurethane insulation, with the bearing plates and side bumpers fabricated from carbon steel with an HDG finish. The shoes are capable of insulating and supporting at temperatures as low as -360°F. These were designed to support pipeline diameter of 42” with overall height of 62” diameter. Regular quality control tests were performed with a standard turn-around time.

Read More

Cryogenic Pipe Supports Designed for a Facility in Massachusetts

September 11, 2017

Cryogenic Pipe Supports Designed for a Facility in Massachusetts

Type: Cryogenic Pipe Supports
Material: Carbon Steel | Polyurethane
Design: -320°F | 36″ – 48″ Dia. | 52″ W x 57″ H x 67″ L

PT&P received an order to custom design 16 cryogenic pipe supports for a contractor in Massachusetts. They needed a pipe forming a T-section lined with insulation and trimmed to accommodate the pipe perpendicular to the shoe length. The overall dimensions of the order are pipe sizes ranging from 36″ to 48″ in diameter, 52″ width and 57″ to 67″ height. Our insulation is designed to support the pipe and its contents. When insulated pipes are supported, the weight of the pipe, the contents, the operating temperature, and the amount of energy loss must be considered. In order to support the pipe and minimize energy loss from heat transfer, a pre-insulated pipe support is necessary. If the material in the pipe is high temperature such as high pressure steam or heating oil, then high temperature insulation is required, and these supports are called hot shoes. If the material is cold, such as liquefied natural gas, cooling water or ammonia, then low temperature insulation is needed, and these types of supports are called cold shoes.

Read More

3-Layer Cryogenic Pipe Shoes for a Light Hydrocarbon Chemical Plant in Texas

June 10, 2017

3-Layer Cryogenic Pipe Shoes for a Light Hydrocarbon Chemical Plant in Texas

Type: Pre-Insulated Pipe Supports for Cryogenic Temperatures
Size: 5.5″ of Insulation / Clamps are 12″ wide
Material: Polyurethane Foam and Carbon Steel with HDG Finish
Design: 18″ Pipe and Cryogenic Operating Temperatures
Testing: Standard Quality Control Tests

These 3-layer pre-insulated cryogenic pipe shoes were custom fabricated by Piping Technology& Products for a light hydrocarbon chemical plant in Texas. The insulation foam is made from polyurethane and the rest of the shoe components from carbon steel with HDG finish. The cold shoes are designed for 18″ pipe, the 3-layers of insulation total is 5.5″ thick, the clamps are 12″ wide, and cryogenic operating temperature. Standard quality control tests were performed prior to shipment.

Read More

Cryogenic Insulated Pipe Supports Designed for a Petrochemical Complex in Louisiana

March 27, 2017

Cryogenic Pipe Supports Designed for a Petrochemical Complex in Louisiana

Type: Pre-Insulated Pipe Supports for Cryogenic Application
Size: 46″ – 52″ Diameter Range | 10 lb. & 20 lb. Density PUF Foam
Material: Hot-dipped Galvanized Carbon Steel | PUF | Polyester Film & Aluminum Foil
Testing: Dimensional and Visual Inspection

PT&P custom designed pre-insulated pipe supports for a cryogenic pipeline at a petrochemical complex in Louisiana. They range in size from 46″ – 52″ diameter and are designed for temperatures down to -20°F. The top portion of the support is 10 lb. density and the bottom is 20 lb. high density polyurethane foam (PUF) insulation. The shoe and bearing plates were fabricated from carbon steel with a hot-dipped galvanized finish. These cold shoes include a vapor barrier comprised of a three layer lamination of polyester film and aluminum foil. Standard quality control tests were performed prior to shipment.

Read More

127 Cryogenic Insulated Pipe Supports Designed for a Chemical Plant

July 25, 2016

127 Cryogenic Insulated Pipe Supports Designed for a Chemical Plant

PT&P custom designed 127 cryogenic insulated pipe supports for a chemical plant in Texas. They are designed for pipe sizes ranging from 1″ – 24″ diameter and operating loads up to 120,517 lb. The insulation is high density polyurethane foam (PUF) ranging from 1″ to 7″ in thickness. The shoe and bearing plates were fabricated from carbon steel with a hot-dipped galvanized finish. The jacket was fabricated from aluminized steel and includes a vapor barrier. Standard Q.C. and dimensional tests were performed prior to shipment.

Read More

Pipe Shields for Beginners: Insulated Pipe Supports… for Commercial Applications

July 14, 2016

This webinar is over, view the recording in the archives

Insulated Pipe SupportThis webinar will give you an introduction to Pipe Shields, Inc. and its unique line of pre-insulated pipe supports, slides, guides and anchors that it developed and patented over it’s 40 year history. It will cover various designs, commercial applications (chilled and heated water lines, HVAC systems and low pressure steam lines), installation and maintenance procedures and the benefits of using pre-insulated pipe supports (vs. doing insulation in the field). This webinar will be delivered by Albert Dizon, General Manager of Pipe Shields, who has been working with pre-insulated pipe supports for 30+ years. Join us and receive some of his experience and wisdom!

Read More